The night cools the house
In summer, if it's cooler outside and the house wants cooling, the ventilation stops recovering heat and brings the night air in. In the morning, the blinds keep it in.
Systems · Ventilation
The house measures CO₂ and humidity in every room and renews the air when needed, recovering much of its warmth or coolness. You sleep with the window shut, free of mosquitoes and noise, and wake up without stuffy air.
Your selection: 0 systems. See it on the house →
Any given day
02:00
In summer, if it's cooler outside and the house wants cooling, the ventilation stops recovering heat and brings the night air in. In the morning, the blinds keep it in.
07:00
Two people, door shut, window shut against mosquitoes: overnight the bedroom's CO₂ climbs. The ventilation notices and steps up a little, at a low speed so it doesn't wake you.
08:30
Bathroom humidity shoots up and the extraction speeds up until it's back to normal, even with the light off. The mirror clears sooner and the grout dries.
21:30
In the living room CO₂ rises fast. The ventilation speeds up without anyone opening the terrace to the mosquitoes, and when the guests leave, it settles back by itself.
How it works
CO₂ and humidity sensors tell the Miniserver when air is needed, and it runs the ventilation — a ducted heat-recovery unit or wall ventilators — together with the climate, windows and alarm.
What it senses
What it controls
Without internet. Without internet it carries on: CO₂, humidity, windows and schedules live in the Miniserver. You lose phone notifications. Night cooling runs on an outdoor sensor, not the online forecast, so it doesn't depend on internet.
In numbers
900 ppm
of CO₂ as an annual average per room is the ceiling Spain's building code (CTE DB HS 3) uses to size ventilation in a new home.
Source: boe.es
1,000 ppm · 60%
of CO₂ and humidity: above these, Loxone's ventilation speeds up by default. I adjust them to your house and to whoever sleeps in each room.
Source: loxone.com
Better together
Installation
In a new home the building code (CTE) already requires hybrid or mechanical ventilation, designed by your engineer. I check the unit accepts control (contact, 0–10 V or Modbus) and run cable to the CO₂ sensors.
A renovation with suspended ceilings has room for a ducted unit. If the ceilings stay, the realistic option is pairs of wall ventilators in bedrooms and the living room.
No chasing walls: pairs of wall ventilators — a 16–18 cm core hole in the façade each and power nearby — plus wireless humidity sensors; CO₂ needs a cable. Before promising, I check the wall.
No small print
Questions
Send me the floor plan and tell me where you notice stuffy air, a damp smell or condensation. Often it's best to measure CO₂ and humidity for two weeks first.